The quick answer

Buy a nebulizer only for people whose doctor or specialist has prescribed nebulised medicine, and plan the consumables before the compressor. Omron’s manual for the C102 Total says the compressor can serve several patients but the nebulizer kit and its accessories are for one patient only, so a clinic or school nurse room needs a separate kit, mask and tube for each person. The same manual asks for cleaning after every use, disinfection once a week, a new air filter after 70 uses or when it changes colour, and gives about one year for the kit, masks and tube under its test conditions. Asthma + Lung UK says to change these parts at least every three to four months. Order spare patient kits and filters with the unit and keep the invoice for the 3-year warranty.

Retail box of the Omron C102 Total compressor nebulizer showing the white compressor with a blue nebulizer cup, a clear face mask and a nasal shower, labelled 2-in-1 Nebulizer with Nasal Shower
Reference photo of the Omron C102 Total (NE-C102-E) box. Package contents, plug type and warranty are confirmed in your quotation.

Start with the prescription, not the device

A nebulizer turns prescribed liquid medicine into a mist to breathe in. Asthma + Lung UK says to buy or use one only if a doctor or specialist recommends it, because they also need to prescribe the medicine to put into it, and to ask the specialist which nebulizer to buy and how it should be serviced.

In a school nurse room or a site clinic, that means the nurse or doctor in charge confirms which students or workers have a nebuliser plan, which medicine and dose, and who may give it. Omron’s manual says the type, dose and regimen of medicine should follow the doctor’s or respiratory specialist’s instructions.

A nebulizer does not replace an emergency call. Asthma + Lung UK advises getting help immediately if a nebuliser is not helping during a flare-up or asthma attack. Put the local emergency number and the escalation steps on the same card as the nebulizer instructions.

References: Asthma + Lung UK: Nebulisers · Omron Healthcare: C102 Total (NE-C102-E) compressor nebulizer instruction manual

One compressor, a separate kit for each patient

The Omron C102 Total (NE-C102-E) manual lists the contents as the compressor, a nebulizer kit, a nasal shower, a 100 cm air tube, a mouthpiece, an adapter, an adult mask, a child mask and the manual, with the air filter fitted in the compressor.

The manual says the compressor is intended for use with several patients, but the nebulizer kit and its accessories are intended for a single patient, and warns not to use them with several patients. If one compressor serves a nurse room, order one accessory set per person who uses it, and label each set with the person’s name.

Omron lists an optional accessory set (NEB-ASKIT-11) with the nebulizer kit, adapter, mouthpiece, nasal piece, adult and child masks, air tube and air filter, and a 3-piece air filter set (3AC408) as a replacement part. Ask for these part numbers on the quotation so spares match the compressor.

References: Omron Healthcare: C102 Total (NE-C102-E) compressor nebulizer instruction manual

Cleaning, disinfection and replacement intervals

Omron’s manual says to clean the parts after each use to remove medicine residue: take the nebulizer kit apart, wash it in warm water with a mild neutral detergent, rinse it in clean hot tap water and let it air dry in a clean place. Asthma + Lung UK also says to air dry the parts and not to wash the tubing.

The manual asks for disinfection once a week, before first use and after a long period without use. It lists chemical disinfectants such as ethanol or sodium hypochlorite, used to the disinfectant’s own instructions, or boiling the kit, mouthpiece, adapter and nasal shower for at least 5 minutes. The masks and the air tube must not be boiled, and the mask straps are removed before disinfecting.

For replacement, the manual gives about one year for the air tube, nebulizer kit, mouthpiece, masks, adapter and nasal shower, based on three 10-minute sessions a day at 23 °C, and notes that frequent use can shorten this. The air filter is replaced after more than 70 uses, if it changes colour or if it gets wet, and is never washed. Asthma + Lung UK advises changing masks, mouthpieces, tubing, filters and the chamber at least every three to four months. Your clinical lead decides which interval the room follows; order spares to match.

References: Omron Healthcare: C102 Total (NE-C102-E) compressor nebulizer instruction manual · Asthma + Lung UK: Nebulisers

Power, room conditions and warranty

The manual gives a 230 V, 50 Hz mains supply and operating conditions of 5 to 40 °C and 15 to 85% relative humidity, and says the unit can stop if it is used above 40 °C or with its vents covered. Use it in an air-conditioned room, on a table with the vents clear, and check the plug type for the room before delivery.

The nebulizer cup holds a minimum of 2 ml and a maximum of 12 ml of medicine, according to the manual. Tell the prescriber which model the room has so the prescribed volume fits.

Omron’s manual gives a 3-year warranty from the date of purchase for manufacturing, workmanship and material defects, and excludes wear of accessories, periodic checks and damage from misuse. Claims need the complete product and the original invoice or receipt, so file the invoice with the asset record. Ask the supplier who handles warranty claims in your country.

References: Omron Healthcare: C102 Total (NE-C102-E) compressor nebulizer instruction manual

Compressor nebulizer order checklist

ItemWhat to confirm
PrescriptionNamed people with a nebuliser plan; medicine, dose and who may give it.
ModelExact compressor model and the medicine volume its cup holds.
Patient kitsOne nebulizer kit, mask or mouthpiece and tube per person, labelled.
MasksAdult and child sizes for the people who will use it.
SparesAccessory sets and air filters by part number, quantity per person.
CleaningDetergent, disinfectant or boiling method, drying space, weekly disinfection record.
ReplacementInterval agreed by the clinical lead for kits, masks, tubes and filters.
Power and roomPlug type, air-conditioned room, vents clear, operating temperature.
Emergency planWhen to stop and call for help; local emergency number on the card.
WarrantyTerm, exclusions, local claims route; invoice kept with the asset record.
Paste your requirements & request a quote

Questions before you order

Can one nebulizer be shared between students or workers?

The Omron C102 Total manual says the compressor can be used for several patients, but the nebulizer kit and accessories are for one patient only. Give each person their own kit, mask and tube.

How often should a nebulizer be cleaned?

Omron’s manual says to clean the parts after each use and disinfect them once a week. Asthma + Lung UK also says to clean it after every use and let the parts air dry.

How often do nebulizer masks, tubes and filters need replacing?

Omron gives about one year for the kit, masks and tube under its test conditions, and a new air filter after 70 uses or if it changes colour. Asthma + Lung UK advises changing parts at least every three to four months. Your clinical lead sets the interval.

Can I buy a nebulizer without a prescription?

Asthma + Lung UK says to buy or use one only if your doctor or specialist recommends it, because they also prescribe the medicine that goes into it.

Do you quote spare kits and filters with the nebulizer?

Yes. Tell us how many people will use it and we quote the compressor, an accessory set per person and air filters as separate lines, with the warranty confirmed in writing.

Sources & scope

This is a purchasing guide. Your qualified safety lead should confirm the current requirements for your site. It is not a clinical protocol or a compliance certificate.

  1. Omron Healthcare: C102 Total (NE-C102-E) compressor nebulizer instruction manual

    Manufacturer instruction manual IM2-NE-C102-E-01-05/2025 (3A4563 rev.00, May 2025), read in its Spanish and Dutch sections. Used for intended use, single-patient nebulizer kits, package contents, accessory set and filter part numbers, cleaning and weekly disinfection, replacement periods, air filter rules, 230 V supply, operating conditions, cup volume and the 3-year warranty. Confirm against the manual supplied with your unit. Checked 10 November 2026.

  2. Asthma + Lung UK: Nebulisers

    UK patient charity guidance (last reviewed 1 March 2023; marked as under review). Used for using a nebuliser only when a doctor or specialist recommends it, asking about servicing, cleaning after every use, air drying, not washing tubing, changing parts at least every three to four months, and getting help if it is not working during an attack. UK guidance; follow your own clinician and regulator. Checked 10 November 2026.

Prepared with AI assistance and checked against the cited sources. No clinical reviewer is claimed. Read our editorial policy or send a correction.

Explore the catalog

These products are available for enquiry. Specifications, contents and delivery are confirmed in your quotation.