The quick answer

Order pelvic slings only for teams trained to use them, and order by size and as single-use stock. SAM Medical’s instructions for use describe the SAM Pelvic Sling II as a circumferential pelvic belt that stabilises suspected pelvic ring fractures during transport, applied by prehospital and medical professionals or trained personnel, and say familiarisation and training are required for safe use. It comes in small (27–45 in), standard (32–50 in) and large (36–54 in) hip circumference sizes, and SAM says the standard size fits 95% of adults. The device is single use, so stock a replacement for every sling carried. Its instructions also say it is MR Conditional at 3 tesla or less and must stay attached to the patient during an MRI.

SAM Pelvic Sling II laid flat, a black and blue padded belt with a perforated black strap passing through an orange buckle and an orange pull strap
Reference photo of the SAM Pelvic Sling II. Size, part number and quantity are confirmed in your quotation.

Who should carry and apply it

A pelvic sling is not a general first aid kit item. SAM Medical’s instructions for use (IFU PS-IS-EN-3, issued April 2023) say the SAM Pelvic Sling II is intended to stabilise pelvic fractures during transport to definitive care, and is indicated for application by prehospital and medical professionals or trained personnel to people who have, or are suspected of having, a pelvic ring fracture where bleeding might occur.

The same document says familiarisation with the device and its instructions, training, and adherence to your organisation’s clinical guidelines and use of PPE are required for safe use. Match the order to the people who will apply it: a site medic, a rescue team or an occupational health clinic, with training booked before the slings go into service.

SAM Medical publishes training videos and an education deck for one-person and two-person application on its website. Ask your medical lead whether that, or a course you already run, covers the device.

References: SAM Medical: SAM Pelvic Sling II instructions for use (PS-IS-EN-3) · SAM Medical: SAM Pelvic Sling II product and training pages

Choose the size by hip circumference

SAM Medical lists three sizes by hip circumference: small, 27–45 in (69–114 cm), part PS300-OB-EN; standard, 32–50 in (81–127 cm), part PS301-OB-EN; and large, 36–54 in (91–137 cm), part PS302-OB-EN. A standard military version, PS301-OD-EN, is also listed.

SAM says its standard size fits 95% of the adult population. We list the large size (PS302-OB-EN) in our catalog; if your team needs standard or small, ask for them on the same quotation and we confirm the part numbers.

A team that may treat a wide range of body sizes, for example on a large construction site or at events, can carry more than one size. Agree the mix with your medical lead and label each bag.

References: SAM Medical: SAM Pelvic Sling II product and training pages · SAM Medical: SAM Pelvic Sling II instructions for use (PS-IS-EN-3)

Single use: plan replacements

The IFU says the device is single use only and that reuse may cause illness, such as infection, or injury through reduced performance. Every sling applied to a patient leaves with them, so hold a replacement for each sling your bags carry and record the reorder on the incident form.

SAM describes the AUTOSTOP buckle as reaching optimal compressive force at 150 N of circumferential pressure, when two prongs click to confirm correct application. That is a design feature, not a substitute for training; check that responders recognise the click on a training unit.

The IFU also asks responders to empty the patient’s pockets before application and to monitor the skin for pressure injury while the sling is in use. Include those points in your team’s quick reference card.

References: SAM Medical: SAM Pelvic Sling II instructions for use (PS-IS-EN-3) · SAM Medical: SAM Pelvic Sling II product and training pages

MRI and hospital handover

The IFU states that non-clinical testing showed the SAM Pelvic Sling II is MR Conditional in a static magnetic field of 3 tesla or less. Because it contains ferromagnetic parts, it must be firmly attached to the patient undergoing an MRI and must not be repositioned or removed in the presence of a powerful magnetic field.

SAM’s product page also describes the sling material as radiolucent. Tell the receiving team which device was applied and when, so they can plan imaging and removal.

The IFU we read does not give storage conditions or a shelf life. Ask the supplier for the current IFU revision with your order, keep it with the bags, and check whether a newer revision changes any of the points above.

References: SAM Medical: SAM Pelvic Sling II instructions for use (PS-IS-EN-3) · SAM Medical: SAM Pelvic Sling II product and training pages

Pelvic sling order checklist

ItemWhat to confirm
UsersSite medic, rescue or clinic team who will apply it; medical lead sign-off.
TrainingDevice familiarisation and training booked before service.
SizesSmall, standard or large by hip circumference; mix per bag.
Part numbersPS300-OB-EN, PS301-OB-EN or PS302-OB-EN on the quotation.
QuantityOne per bag plus a replacement for each, since it is single use.
Training unitA separate unit for practice, not taken from response stock.
Quick referenceEmpty pockets, check skin, note time applied.
HandoverDevice and time given to the receiving team; MR Conditional at 3 T or less.
IFUCurrent revision supplied and kept with the bags.
Paste your requirements & request a quote

Questions before you order

Who can apply a SAM Pelvic Sling II?

SAM Medical’s instructions say prehospital and medical professionals or trained personnel, and that familiarisation and training are required for safe use.

Which size should we order?

SAM lists small (27–45 in), standard (32–50 in) and large (36–54 in) hip circumference sizes and says the standard size fits 95% of adults. Agree the mix with your medical lead.

Can a pelvic sling be reused?

No. SAM’s instructions say the SAM Pelvic Sling II is single use only. Keep a replacement for every sling you carry.

Can the patient have an MRI with the sling on?

SAM’s instructions say it is MR Conditional at 3 tesla or less, must stay firmly attached and must not be moved or removed near a powerful magnetic field. Tell the receiving team it was applied.

Sources & scope

This is a purchasing guide. Your qualified safety lead should confirm the current requirements for your site. It is not a clinical protocol or a compliance certificate.

  1. SAM Medical: SAM Pelvic Sling II instructions for use (PS-IS-EN-3)

    Manufacturer IFU, issue date 2023-04, hosted by a distributor; SAM’s own link serves a newer revision (PS-IS-EN-4) that could not be read. Used for intended use, indications, training, sizes, single use, precautions and the MR Conditional statement. Confirm against the IFU supplied with your stock. Checked 13 November 2026.

  2. SAM Medical: SAM Pelvic Sling II product and training pages

    Manufacturer product page and training page (undated). Used for part numbers and sizes, the 95% standard-size statement, single use, the AUTOSTOP buckle at 150 N, radiolucent material and training resources. Checked 13 November 2026.

Prepared with AI assistance and checked against the cited sources. No clinical reviewer is claimed. Read our editorial policy or send a correction.