A stair evacuation chair is a building decision as much as a purchase. Before ordering, confirm the maximum passenger weight in the manufacturer’s manual, the stair angle and stair types it must not be used on, where and how its storage cabinet is fixed, how operators will be trained and practise, and what the warranty covers, including consumable parts such as tracks. UK government guidance also warns that a chair is not an automatic solution for every wheelchair user, so it should sit inside a wider evacuation plan that your fire safety lead owns.

Start with the evacuation plan, not the chair
UK Home Office guidance on means of escape for disabled people says evacuation chairs should not be considered an automatic solution for wheelchair users, notes that not everyone can transfer into one or stay seated in it, and says chairs should be accompanied by a full system of escape. It is a UK document, but the point carries over: the chair is one part of a plan.
Before asking for a quotation, have your fire safety lead identify who may need assistance, on which floors, and which stairs they would use. The same guidance discusses keeping a chair close to the person it is allocated to, or at a suitable refuge, and notes that one on each staircase at each level may be an expensive option, with other arrangements acceptable depending on the circumstances. Those choices set the quantity and the locations on your order.
Write the locations on the request: floor, stair core and refuge or landing. A quotation for “one chair” without locations cannot tell you whether a cabinet, bracket or extra unit is needed.
References: Home Office (GOV.UK): Fire safety risk assessment, means of escape for disabled people
Check the load rating and the stairs against the manual
Take limits from the manual of the exact model, not a product card. The Garaventa Evacu-Trac CD8 owner’s manual (item 12440 Rev E) says not to use it with a passenger heavier than 180 kg (400 lb). Our catalog lists the same model at 182 kg (400 lb); the pound figure is the same and the kilogram figures are rounded differently, so record the manual’s wording.
The same manual gives a maximum stair angle of 40° and says not to use the chair on curved or spiral stairs, irregular or insecure stairs, or stairs with loose carpet. Measure or ask your building team for the angle and finish of each stair core on the plan, and flag any curved, spiral or carpeted flights before choosing a model.
The manual does not give a minimum stair width or landing size. If landings are tight, ask the supplier for the chair’s dimensions and turning needs for your stairs, and have your fire safety lead check them on site.
References: Garaventa Lift: Evacu-Trac CD8 owner’s manual, item 12440 Rev E
Storage cabinet and fixing
Ask whether the cabinet or wall bracket is included or a separate line. The CD8 manual describes a surface-mounted storage cabinet fixed with lag bolts, with different hole counts for stud walls and for concrete or block walls, and recommends an accessible spot with room for a transfer, such as a large upper landing near the stair to be used.
Give the supplier the wall type at each location, and agree who drills and fixes the cabinet. Fixing into a fire-rated stair core or a landlord’s wall may need building management approval, so name the person who will give it.
Label each cabinet with the floor and stair it serves, so the chair is returned to the right place after training or use.
References: Garaventa Lift: Evacu-Trac CD8 owner’s manual, item 12440 Rev E
Training, practice and what the warranty covers
The Home Office guidance says a chair is operated by one or two people, needs training and practice, and that a training system should be put in place when chairs are bought. The CD8 manual says only properly trained people should operate it and recommends monthly practice. Ask the supplier what training material comes with the chair and whether hands-on training is quoted separately.
Read the warranty terms before comparing prices. The CD8 manual gives 15 years on the unit, excluding consumables, and 2 years on consumable components such as rubber tracks, brake components and soft materials, with repair or replacement at the manufacturer’s discretion. Ask whether replacement tracks and other consumables can be quoted for later.
The manual also says to keep the tracks clean and to replace them if they are cut, cracked or deteriorating. Add the chair to your inspection rota so someone checks it between practice sessions.
References: Home Office (GOV.UK): Fire safety risk assessment, means of escape for disabled people · Garaventa Lift: Evacu-Trac CD8 owner’s manual, item 12440 Rev E
Worked example: a six-floor office with two stair cores
This is an illustrative purchasing exercise, not a fire engineering assessment or a MedSphere quotation. An office tenant on floors 4 to 6 has two employees who have agreed personal evacuation arrangements, both on floor 5, and occasional visitors.
The fire safety lead decides on one chair at the floor 5 refuge of stair core A, near both employees, and one at the floor 6 landing of core B for visitors. The building manager confirms both cores are straight flights; core B has carpet on the landings only. The buyer’s request lists two chairs, two cabinets, the wall type at each landing, who will fix them, training for six staff, and spare tracks as a separate future line.
Two quotes arrive: one includes cabinets, the other does not. Listing cabinets, training and the warranty terms side by side shows the real difference before the order is approved.
References:
Stair evacuation chair purchasing checklist
| Item | What to confirm |
|---|---|
| Plan and locations | Who may need help, which floors and stair cores, and each chair’s refuge or landing. |
| Exact model | Manufacturer, model and the manual edition you are relying on. |
| Passenger weight | Maximum load as written in the manual, in kg and lb. |
| Stairs | Angle, straight or curved, finish and landings for each stair core; flag spiral or carpeted flights. |
| Cabinet or bracket | Included or separate; wall type; who fixes it and who approves fixing. |
| Training | Training material supplied, hands-on training quoted, number of operators, practice plan. |
| Warranty | Term for the unit and for consumables such as tracks and brake parts. |
| Inspection | Who checks the chair and tracks, how often, and where spare parts come from. |
Questions before you order
Is an evacuation chair enough for wheelchair users?
Not on its own. UK government guidance says chairs are not an automatic solution, that some people cannot transfer into one, and that they should be part of a full escape plan. Your fire safety lead decides the arrangements for each person.
How heavy a passenger can an evacuation chair carry?
It depends on the model. The Garaventa Evacu-Trac CD8 manual gives 180 kg (400 lb). Use the limit in the manual of the exact model you are offered.
Can an evacuation chair be used on any staircase?
No. The CD8 manual gives a 40° maximum stair angle and excludes curved or spiral stairs, irregular stairs and loose carpet. Check each stair core against the manual of the model you buy.
Do you quote the cabinet and training with the chair?
Yes. Send the number of chairs, the locations and wall types, and the training you need, and we quote the chair, cabinet and any training as separate lines.
Sources & scope
This is a purchasing guide. Your qualified safety lead should confirm the current requirements for your site. It is not a clinical protocol or a compliance certificate.
- Garaventa Lift: Evacu-Trac CD8 owner’s manual, item 12440 Rev E
Manufacturer manual (printed in Canada, undated), hosted by California State University, Los Angeles. Used for the 180 kg (400 lb) passenger limit, 40° stair angle and excluded stair types, cabinet fixing, training and monthly practice, track care, and the 15-year unit and 2-year consumables warranty. Confirm the manual and warranty supplied with your unit. Checked 3 November 2026.
- Home Office (GOV.UK): Fire safety risk assessment, means of escape for disabled people
UK guidance, first published 2 March 2021, updated 12 September 2023. Used for chairs not being an automatic solution, operation by one or two trained people, training when chairs are bought, and storage near the allocated person or a refuge. Not a UAE or GCC requirement; follow your local civil defence rules and fire safety lead. Checked 3 November 2026.
Prepared with AI assistance and checked against the cited sources. No clinical reviewer is claimed. Read our editorial policy or send a correction.